Edit esp-officeduallights.yaml
This commit is contained in:
@@ -365,6 +365,28 @@ mqtt:
|
||||
then:
|
||||
- light.turn_off: light_2
|
||||
|
||||
# Mirror shared overhead status from esp-officelights onto light_2. This handles the
|
||||
# case where the main lightswitch's overhead timer finishes and turns off the overhead.
|
||||
# State guards prevent ping-pong with the command topic handlers above.
|
||||
- topic: "${mqtt_shared_overhead_status_topic}"
|
||||
payload: "${mqtt_command_on}"
|
||||
then:
|
||||
- if:
|
||||
condition:
|
||||
lambda: "return !id(relay_2).state;"
|
||||
then:
|
||||
- light.turn_on: light_2
|
||||
|
||||
- topic: "${mqtt_shared_overhead_status_topic}"
|
||||
payload: "${mqtt_command_off}"
|
||||
then:
|
||||
- script.stop: relay_2_timer_script
|
||||
- if:
|
||||
condition:
|
||||
lambda: "return id(relay_2).state;"
|
||||
then:
|
||||
- light.turn_off: light_2
|
||||
|
||||
#:########################################################################################:#
|
||||
# SCRIPT COMPONENT:
|
||||
# Independent per-relay timer scripts
|
||||
|
||||
Reference in New Issue
Block a user