#:########################################################################################:# # TITLE: MAIN HALLWAY LIGHTSWITCH 1 (BK7231N) # zorruno.com layout v1.1 2026 #:########################################################################################:# # REPO: # https://home.fox.co.nz/gitea/zorruno/zorruno-homeassistant/src/branch/master/esphome/esp-mainhallwaylights1.yaml #:########################################################################################:# # VERSIONS: # V1.1 2026-04-03 Updated yaml to zorruno layout V1.1; corrected KS-811 single naming and operation notes; updated BK7231N single-switch pin mapping # V1.0 2026-04-03 Initial #:########################################################################################:# # HARDWARE: # - Zemismart KS-811 Single push button # - BK7231N based switch # - BK72XX board: generic-bk7231n-qfn32-tuya # - BK7231N single-switch pin mapping checked against KS-811 BK references #:########################################################################################:# # OPERATION NOTES: # - Main hallway switch with 1 output: # 1) Main Hallway Lights # - A single press of the physical button toggles Relay 1 ON/OFF # - Status LED uses P22 #:########################################################################################:# # MQTT COMMANDS: # - None #:########################################################################################:# # OFFLINE NOTES: # - a) Home Assistant offline (network and MQTT online): # - Device remains on WiFi and MQTT # - Physical button still toggles relay locally # - b) MQTT offline (or Home Assistant and MQTT offline): # - Physical button still toggles relay locally # - Remote control/state sync is unavailable until MQTT returns # - c) Entire WiFi/network offline: # - Physical button still toggles relay locally # - Accurate time is not needed; SNTP is not used #:########################################################################################:# #:########################################################################################:# # SUBSTITUTIONS: Specific device variable substitutions # If NOT using a secrets file, just replace these with the passwords etc (in quotes) #:########################################################################################:# substitutions: # Device Naming device_name: "esp-mainhallwaylights1" friendly_name: "Main Hallway Lightswitch (1)" description_comment: "BK7231N - Main Hallway Lightswitch using a Zemismart KS-811 Single Push Button. Main Hallway Lights (1) (Layout V1.1)" device_area: "Main Hallway" # Allows ESP device to be automatically linked to an 'Area' in Home Assistant. # Project Naming project_name: "Zemismart Technologies.KS-811 Single BK7231N" # Project Details project_version: "v1.1" # Project V denotes release of yaml file, allowing checking of deployed vs latest version # Passwords api_key: !secret esp-api_key # unfortunately you can't use substitutions inside secrets names ota_pass: !secret esp-ota_pass # unfortunately you can't use substitutions inside secrets names static_ip_address: !secret esp-mainhallwaylights1_ip mqtt_command_main_topic: !secret mqtt_command_main_topic #mqtt_status_main_topic: !secret mqtt_status_main_topic # If we are changing IP addresses, you must update the current IP address here, otherwise it remains # Don't forget to switch it back when changed. current_ip_address: ${static_ip_address} # Device Settings log_level: "INFO" # Define logging level: NONE, ERROR, WARN, INFO, DEBUG (Default), VERBOSE, VERY_VERBOSE update_interval: "60s" # update time for for general sensors etc # Default relay restore mode # Options: RESTORE_DEFAULT_OFF, RESTORE_DEFAULT_ON, ALWAYS_ON, ALWAYS_OFF relay_restore_mode: "RESTORE_DEFAULT_OFF" # Switch Naming switch_1_name: "Main Hallway Lights" #:########################################################################################:# # PACKAGES: Included Common Packages # https://esphome.io/components/packages.html #:########################################################################################:# packages: #### WIFI, Network (Static/DHCP/IPV6 etc), Fallback AP, Safemode #### common_wifi: !include file: common/network_common.yaml vars: local_device_name: "${device_name}" local_static_ip_address: "${static_ip_address}" local_ota_pass: "${ota_pass}" local_current_ip_address: "${current_ip_address}" #### HOME ASSISTANT API (choose encryption or no encryption options) #### common_api: !include file: common/api_common.yaml #file: common/api_common_noencryption.yaml vars: local_api_key: "${api_key}" #### MQTT #### common_mqtt: !include file: common/mqtt_common.yaml vars: local_device_name: "${device_name}" #### WEB PORTAL #### #common_webportal: !include common/webportal_common.yaml #### SNTP (Only use if you want/need accurate timeclocks) #### #common_sntp: !include common/sntp_common.yaml #### DIAGNOSTICS Sensors #### diag_basic: !include common/include_basic_diag_sensors.yaml #diag_more: !include common/include_more_diag_sensors.yaml #diag_debug: !include common/include_debug_diag_sensors.yaml #diag_resetcount: !include common/include_resetcount_diag_sensors.yaml #:########################################################################################:# # PACKAGE ITEM REMOVALS / OVERRIDES: #:########################################################################################:# wifi: min_auth_mode: !remove # The WPA2 only works on esp32/8266 reboot_timeout: 15min # override the selection from the common package fast_connect: false # optional; force off in case package vars change mqtt: keepalive: 15s # overriding the value from the common package #:########################################################################################:# # ESPHOME: # https://esphome.io/components/esphome.html #:########################################################################################:# esphome: name: "${device_name}" friendly_name: "${friendly_name}" comment: "${description_comment}" # Appears on the esphome page in HA area: "${device_area}" project: name: "${project_name}" version: "${project_version}" #:########################################################################################:# # BUILD FOR BK CHIPSET: # bk72xx # https://devices.esphome.io/board/bk72xx/ #:########################################################################################:# bk72xx: board: generic-bk7231n-qfn32-tuya #:########################################################################################:# # LOGGER: # https://esphome.io/components/logger.html #:########################################################################################:# logger: level: "${log_level}" # INFO Level suggested, or DEBUG for testing baud_rate: 0 # set to 0 for no logging via UART, needed if you are using it for other serial things (eg PZEM) id: logger_id #:########################################################################################:# # STATUS LED: # https://esphome.io/components/status_led.html #:########################################################################################:# status_led: pin: number: P22 # GPIO22 inverted: true #:########################################################################################:# # BINARY SENSORS: # https://esphome.io/components/binary_sensor/ #:########################################################################################:# binary_sensor: - platform: gpio id: button_1 internal: true pin: number: P24 # GPIO24 mode: input: true pullup: true inverted: true filters: - delayed_on: 20ms on_press: - switch.toggle: Relay_1 #:########################################################################################:# # SWITCH COMPONENT: # https://esphome.io/components/switch/ #:########################################################################################:# switch: - platform: gpio name: "Relay 1: ${switch_1_name}" pin: P16 # GPIO16 id: Relay_1 restore_mode: ${relay_restore_mode}