#:########################################################################################:# # TITLE: BEDROOM 2 LIGHTSWITCH # zorruno.com layout v1.1 2026 #:########################################################################################:# # REPO: # https://home.fox.co.nz/gitea/zorruno/zorruno-homeassistant/src/branch/master/esphome/esp-bedrm2lights.yaml #:########################################################################################:# # VERSIONS: # V3.6 2026-03-04 Updated yaml to zorruno layout V1.1 # V3.5 2025-07-24 YAML tidyups #:########################################################################################:# # HARDWARE: # - Zemismart KS-811 Double push button (KS-811-2) # pinout/schematic: https://community.home-assistant.io/t/zemismart-ks-811-working-with-esphome/ #:########################################################################################:# # OPERATION NOTES: # - 2 button wall switch controlling 2 relays # - Button 1 toggles Relay 1 (Main Lights) # - Button 2 toggles Relay 2 (Desk Lights) # - Status LED on GPIO2 #:########################################################################################:# # MQTT COMMANDS: # - None (local relay control only; MQTT package is included for diagnostics/standardization) #:########################################################################################:# # OFFLINE NOTES: # a) Home Assistant OFFLINE, but Network ONLINE # - Physical buttons still toggle the relays locally # - If MQTT is online, any standard MQTT diagnostics from your common package continue to publish # - HA entities will be unavailable until HA returns # b) MQTT OFFLINE (but WiFi/Network and HA API ONLINE) # - Physical buttons still toggle the relays locally # - HA control via API remains available (switch entities still work) # - MQTT diagnostics/publishes from common_mqtt will fail while MQTT is down # c) Entire WiFi/Network OFFLINE # - Physical buttons still toggle the relays locally (standalone operation) # - No HA API access and no MQTT connectivity until network returns # - Accurate time is NOT needed (SNTP not required) for core operation (no time-of-day schedules) #:########################################################################################:# #:########################################################################################:# # SUBSTITUTIONS: Specific device variable substitutions # If NOT using a secrets file, just replace these with the passwords etc (in quotes) #:########################################################################################:# substitutions: # Device Naming device_name: "esp-bedrm2lights" friendly_name: "Bedroom 2 Lightswitch (2)" description_comment: "Bedroom 2 Main Lightswitch using a Zemismart KS-811 Double Push Button. Main Lights (1), Desk Lights (2) (Layout V1.1)" device_area: "Bedroom 2" # Allows ESP device to be automatically linked to an 'Area' in Home Assistant. # Project Naming project_name: "Zemismart Technologies.KS-811 Double" # Project Details project_version: "v3.6" # Project V denotes release of yaml file, allowing checking of deployed vs latest version # Passwords and Secrets api_key: !secret esp-api_key # unfortunately you can't use substitutions inside secrets names ota_pass: !secret esp-ota_pass # unfortunately you can't use substitutions inside secrets names static_ip_address: !secret esp-bedrm2lights_ip # If we are changing IP addresses, you must update the current IP address here, otherwise it remains # Don't forget to switch it back when changed. current_ip_address: ${static_ip_address} # Device Settings log_level: "INFO" # Define logging level: NONE, ERROR, WARN, INFO, DEBUG (Default), VERBOSE, VERY_VERBOSE update_interval: "60s" # update time for general sensors etc # Switch Naming switch_1_name: "Main Lights" switch_2_name: "Desk Lights" #:########################################################################################:# # PACKAGES: Included Common Packages # https://esphome.io/components/packages.html #:########################################################################################:# packages: #### WIFI, Network (Static/DHCP/IPV6 etc), Fallback AP, Safemode #### common_wifi: !include file: common/network_common.yaml vars: local_device_name: "${device_name}" local_static_ip_address: "${static_ip_address}" local_ota_pass: "${ota_pass}" local_current_ip_address: "${current_ip_address}" #### HOME ASSISTANT API (choose encryption or no encryption options) #### common_api: !include file: common/api_common.yaml #file: common/api_common_noencryption.yaml vars: local_api_key: "${api_key}" #### MQTT #### common_mqtt: !include file: common/mqtt_common.yaml vars: local_device_name: "${device_name}" #### WEB PORTAL #### #common_webportal: !include common/webportal_common.yaml #### SNTP (Only use if you want/need accurate timeclocks) #### common_sntp: !include common/sntp_common.yaml #### DIAGNOSTICS Sensors #### diag_basic: !include common/include_basic_diag_sensors.yaml diag_more: !include common/include_more_diag_sensors.yaml diag_debug: !include common/include_debug_diag_sensors.yaml #diag_resetcount: !include common/include_resetcount_diag_sensors.yaml #:########################################################################################:# # ESPHOME: # https://esphome.io/components/esphome.html #:########################################################################################:# esphome: name: "${device_name}" friendly_name: "${friendly_name}" comment: "${description_comment}" # Appears on the esphome page in HA area: "${device_area}" project: name: "${project_name}" version: "${project_version}" #on_boot: # priority: 200 # then: # - switch.turn_on: Relay_2 #:########################################################################################:# # ESP PLATFORM AND FRAMEWORK: # https://esphome.io/components/esp8266/ #:########################################################################################:# esp8266: board: esp01_1m early_pin_init: false # Recommended false where switches are involved. Defaults to true. board_flash_mode: dout # Default is dout #:########################################################################################:# # LOGGING: ESPHome Logging Enable # https://esphome.io/components/logger.html #:########################################################################################:# logger: level: "${log_level}" # INFO suggested, or DEBUG for testing #baud_rate: 0 # set to 0 for no logging via UART, needed if using UART for other serial devices #esp8266_store_log_strings_in_flash: false #tx_buffer_size: 64 #:########################################################################################:# # STATUS LED: # https://esphome.io/components/status_led.html #:########################################################################################:# status_led: pin: number: GPIO2 inverted: true #:########################################################################################:# # BINARY SENSORS: # https://esphome.io/components/binary_sensor/ # Buttons for KS-811-2 are GPIO16, GPIO5 #:########################################################################################:# binary_sensor: - platform: gpio pin: number: GPIO16 mode: INPUT inverted: true use_interrupt: false # GPIO16 does not support interrupts so use polling (suppresses warning). name: "Button 1: ${switch_1_name}" on_press: - switch.toggle: Relay_1 - platform: gpio pin: number: GPIO5 mode: INPUT inverted: true name: "Button 2: ${switch_2_name}" on_press: - switch.toggle: Relay_2 # KS-811-2 is a double only # - platform: gpio # pin: # number: GPIO4 # mode: INPUT # inverted: true # name: "Button 3: ${switch_3_name}" # on_press: # - switch.toggle: Relay_3 #:########################################################################################:# # SWITCH COMPONENT: # https://esphome.io/components/switch/ # Relays for KS-811-2 are GPIO13, GPIO12 #:########################################################################################:# switch: - platform: gpio name: "Relay 1: ${switch_1_name}" pin: GPIO13 id: Relay_1 - platform: gpio name: "Relay 2: ${switch_2_name}" pin: GPIO12 id: Relay_2 # KS-811-2 is a double only # - platform: gpio # name: "Relay 3: ${switch_3_name}" # pin: GPIO14 # id: Relay_3