# MAIN BATHROOM FAN/HEAT COMBO SWITCH
|
|
# V1.1 2025-08-26 Minor Changes (MQTT)
|
|
# V1.0 2025-06-01 Initial Version
|
|
#############################################
|
|
# Zemismart KS-811 Triple push button
|
|
# pinout/schematic https://community.home-assistant.io/t/zemismart-ks-811-working-with-esphome/
|
|
#
|
|
# NOTES
|
|
# -
|
|
#
|
|
#############################################
|
|
#############################################
|
|
|
|
#############################################
|
|
# SPECIFIC DEVICE VARIABLE SUBSTITUTIONS
|
|
# If NOT using a secrets file, just replace these with the passwords etc (in quotes)
|
|
#############################################
|
|
substitutions:
|
|
# Device Naming
|
|
device_name: "esp-mainbathfancombo"
|
|
friendly_name: "Main Bathroom Fan/Heat Combo Switch (2)"
|
|
description_comment: "Main Bathroom Fan/Heat Switch using a Zemismart KS-811 Double Push Button. Extract Fan (1), IR heater (2)"
|
|
device_area: "Laundry" # Allows ESP device to be automatically linked to an 'Area' in Home Assistant.
|
|
|
|
# Project Naming
|
|
project_name: "Zemismart Technologies.KS-811-2 (Double)" # Project Details
|
|
project_version: "v1.1" # Project V denotes release of yaml file, allowing checking of deployed vs latest version
|
|
|
|
entity_prefix: "Main Bathroom" # Simple device name where we want to prefix a sensor or switch, eg "Load" Current.
|
|
|
|
# Passwords
|
|
api_key: !secret esp-api_key # unfortunately you can't use substitutions inside secrets names
|
|
ota_pass: !secret esp-ota_pass # unfortunately you can't use substitutions inside secrets names
|
|
static_ip_address: !secret esp-mainbathfancombo_ip
|
|
mqtt_command_main_topic: !secret mqtt_command_main_topic
|
|
#mqtt_status_main_topic: !secret mqtt_status_main_topic
|
|
|
|
# Device Settings
|
|
#relay_icon: "mdi:heating-coil"
|
|
log_level: "INFO" # Define logging level: NONE, ERROR, WARN, INFO, DEBUG (Default), VERBOSE, VERY_VERBOSE
|
|
update_interval: "60s" # update time for for general sensors etc
|
|
|
|
# MQTT REMOTE Controls
|
|
mqtt_remote_device1_name: "masterbath-towelrail"
|
|
mqtt_remote_device1_command_topic: "${mqtt_command_main_topic}/${mqtt_remote_device1_name}/operation"
|
|
mqtt_remote_device1_command1: "BOOST"
|
|
|
|
##########################################################################################
|
|
# PACKAGES: Included Common Packages
|
|
# https://esphome.io/components/packages.html
|
|
##########################################################################################
|
|
packages:
|
|
common_wifi: !include
|
|
file: common/network_common.yaml
|
|
vars:
|
|
local_device_name: "${device_name}"
|
|
local_static_ip_address: "${static_ip_address}"
|
|
local_ota_pass: "${ota_pass}"
|
|
common_api: !include
|
|
file: common/api_common.yaml
|
|
vars:
|
|
local_api_key: "${api_key}"
|
|
#common_webportal: !include
|
|
# file: common/webportal_common.yaml
|
|
common_mqtt: !include
|
|
file: common/mqtt_common.yaml
|
|
vars:
|
|
local_device_name: "${device_name}"
|
|
common_sntp: !include
|
|
file: common/sntp_common.yaml
|
|
common_general_sensors: !include
|
|
file: common/sensors_common.yaml
|
|
vars:
|
|
local_friendly_name: "${friendly_name}"
|
|
local_update_interval: "${update_interval}"
|
|
|
|
#############################################
|
|
# ESPHome
|
|
# https://esphome.io/components/esphome.html
|
|
#############################################
|
|
esphome:
|
|
name: ${device_name}
|
|
friendly_name: ${friendly_name}
|
|
comment: ${description_comment} #Appears on the esphome page in HA
|
|
area: ${device_area}
|
|
project:
|
|
name: "${project_name}"
|
|
version: "${project_version}"
|
|
platformio_options:
|
|
build_flags:
|
|
- "-Os" # optimize for size
|
|
- "-Wl,--gc-sections" # drop unused code/data
|
|
- "-fno-exceptions" # strip C++ exceptions
|
|
- "-fno-rtti" # strip C++ RTTI
|
|
# on_boot:
|
|
# priority: 200
|
|
# then:
|
|
# - switch.turn_on: Relay_3
|
|
|
|
#############################################
|
|
# ESP Platform and Framework
|
|
# https://esphome.io/components/esp32.html
|
|
#############################################
|
|
esp8266:
|
|
board: esp01_1m
|
|
early_pin_init: False # Initialise pins early to known values. Recommended false where switches are involved. Defaults to True.
|
|
board_flash_mode: dout # Default is dout
|
|
|
|
#############################################
|
|
# ESPHome Logging Enable
|
|
# https://esphome.io/components/logger.html
|
|
#############################################
|
|
logger:
|
|
level: "${log_level}" #INFO Level suggested, or DEBUG for testing
|
|
#baud_rate: 0 #set to 0 for no logging via UART, needed if you are using it for other serial things (eg PZEM)
|
|
#esp8266_store_log_strings_in_flash: false
|
|
#tx_buffer_size: 64
|
|
|
|
#############################################
|
|
# STATUS LED
|
|
# https://esphome.io/components/status_led.html
|
|
#############################################
|
|
# Status LED for KS-811 is gpio2
|
|
#############################################
|
|
status_led:
|
|
pin:
|
|
number: GPIO2
|
|
inverted: yes
|
|
|
|
#############################################
|
|
# BINARY SENSORS
|
|
# https://esphome.io/components/binary_sensor/
|
|
#############################################
|
|
# Buttons for KS-811-2 are GPIO16, GPIO05
|
|
#############################################
|
|
binary_sensor:
|
|
- platform: gpio
|
|
pin:
|
|
number: GPIO16
|
|
mode: INPUT
|
|
inverted: True
|
|
name: "Button 1: Extract Fan"
|
|
on_press:
|
|
- switch.toggle: "Relay_1"
|
|
|
|
- platform: gpio
|
|
pin:
|
|
number: GPIO05
|
|
mode: INPUT
|
|
inverted: true
|
|
name: "Button 2: IR Heater"
|
|
filters:
|
|
- delayed_on: 20ms
|
|
- delayed_off: 20ms
|
|
|
|
on_multi_click:
|
|
# ── Single click: one quick press & release ─────────────────
|
|
- timing:
|
|
- ON for at most 400ms
|
|
- OFF for at least 200ms
|
|
then:
|
|
- switch.toggle: "Relay_2"
|
|
|
|
# ── Double click: two quick presses/releases ───────────────
|
|
- timing:
|
|
- ON for at most 400ms
|
|
- OFF for at most 400ms
|
|
- ON for at most 400ms
|
|
- OFF for at least 200ms
|
|
then:
|
|
- mqtt.publish:
|
|
topic: "${mqtt_remote_device1_command_topic}"
|
|
payload: "${mqtt_remote_device1_command1}"
|
|
|
|
#############################################
|
|
# SWITCH COMPONENT
|
|
# https://esphome.io/components/switch/
|
|
#############################################
|
|
# Relays for KS-811-2 are GPIO13, GPIO12
|
|
#############################################
|
|
switch:
|
|
- platform: gpio
|
|
name: "Relay 1: Extract Fan"
|
|
pin: GPIO13
|
|
id: Relay_1
|
|
|
|
- platform: gpio
|
|
name: "Relay 2: IR Heater"
|
|
pin: GPIO12
|
|
id: Relay_2
|
|
# Always run the fan when IR heater on. Not critical for this heat/lamp product
|
|
# as it has its own failsafes and fan switching on temp, but an added safety measure
|
|
on_turn_on:
|
|
switch.turn_on: "Relay_1"
|
|
|