various incl esphome devices

This commit is contained in:
root
2025-02-15 17:16:41 +13:00
parent 70ed59fef8
commit 92a54f7ae5
12 changed files with 1758 additions and 489 deletions

View File

@@ -0,0 +1,471 @@
"""Tuya Din Power Meter."""
import logging
from zigpy.profiles import zha
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, GreenPowerProxy, Groups, Ota, Scenes, Time
from zigpy.zcl.clusters.homeautomation import ElectricalMeasurement
from zigpy.zcl.clusters.smartenergy import Metering
from zhaquirks import Bus, LocalDataCluster
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.tuya import TuyaManufClusterAttributes, TuyaOnOff, TuyaSwitch
TUYA_TOTAL_ENERGY_ATTR = 0x0211 #energy
TUYA_CURRENT_ATTR = 0x0212 #current
TUYA_POWER_ATTR = 0x0213 #power
TUYA_VOLTAGE_ATTR = 0x0214 #voltaje
TUYA_DIN_SWITCH_ATTR = 0x0101 #switch
SWITCH_EVENT = "switch_event"
"""Hiking Power Meter Attributes"""
HIKING_DIN_SWITCH_ATTR = 0x0110
HIKING_TOTAL_ENERGY_DELIVERED_ATTR = 0x0201
HIKING_TOTAL_ENERGY_RECEIVED_ATTR = 0x0266
HIKING_VOLTAGE_CURRENT_ATTR = 0x0006
HIKING_POWER_ATTR = 0x0267
HIKING_FREQUENCY_ATTR = 0x0269
HIKING_POWER_FACTOR_ATTR = 0x026F
HIKING_TOTAL_REACTIVE_ATTR = 0x026D
HIKING_REACTIVE_POWER_ATTR = 0x026E
"""MatSee Power Meter Attributes"""
MATSEE_DPID_POWER_TOTAL_ID_ATTR = 0x0273
MATSEE_DPID_POWER_ID_A_ATTR = 0x0265
MATSEE_DPID_POWER_ID_B_ATTR = 0x0269
MATSEE_DPID_POWER_DIRECTION_ID_A_ATTR = 0x0266
MATSEE_DPID_POWER_DIRECTION_ID_B_ATTR = 0x0268
MATSEE_DPID_FORWARD_ENERGY_TOTAL_A_ATTR = 0x026A
MATSEE_DPID_REVERSE_ENERGY_TOTAL_A_ATTR = 0x026B
MATSEE_DPID_FORWARD_ENERGY_TOTAL_B_ATTR = 0x026C
MATSEE_DPID_REVERSE_ENERGY_TOTAL_B_ATTR = 0x026D
MATSEE_DPID_POWER_FACTOR_A_ATTR = 0x026E
MATSEE_DPID_POWER_FACTOR_B_ATTR = 0x0279
MATSEE_DPID_POWER_FREQ_ATTR = 0x026F
MATSEE_DPID_VOLTAGE_A_ATTR = 0x0270
MATSEE_DPID_CURRENT_A_ATTR = 0x0271
MATSEE_DPID_CURRENT_B_ATTR = 0x0272
MATSEE_DPID_UPDATE_RATE_ATTR = 0x0281
MATSEE_DPID_VOLTAGE_A_COEF_ATTR = 0x0274
MATSEE_DPID_CURRENT_A_COEF_ATTR = 0x0275
MATSEE_DPID_POWER_A_COEF_ATTR = 0x0276
MATSEE_DPID_ENERGY_A_COEF_ATTR = 0x0277
MATSEE_DPID_ENERGY_A_COEF_REV_ATTR = 0x027F
MATSEE_DPID_FREQ_COEF_ATTR = 0x027A
MATSEE_DPID_CURRENT_B_COEF_ATTR = 0x027B
MATSEE_DPID_POWER_B_COEF_ATTR = 0x027C
MATSEE_DPID_ENERGY_B_COEF_ATTR = 0x027D
MATSEE_DPID_ENERGY_B_COEF_REV_ATTR = 0x0280
_LOGGER = logging.getLogger(__name__)
class TuyaManufClusterDinPower(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the Tuya Power Meter device."""
attributes = {
TUYA_TOTAL_ENERGY_ATTR: ("energy", t.uint32_t, True),
TUYA_CURRENT_ATTR: ("current", t.int16s, True),
TUYA_POWER_ATTR: ("power", t.uint16_t, True),
TUYA_VOLTAGE_ATTR: ("voltage", t.uint16_t, True),
TUYA_DIN_SWITCH_ATTR: ("switch", t.uint8_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == TUYA_TOTAL_ENERGY_ATTR:
self.endpoint.smartenergy_metering.energy_deliver_reported(value / 100)
elif attrid == TUYA_CURRENT_ATTR:
self.endpoint.electrical_measurement.current_reported(value)
elif attrid == TUYA_POWER_ATTR:
self.endpoint.electrical_measurement.power_reported(value / 10)
elif attrid == TUYA_VOLTAGE_ATTR:
self.endpoint.electrical_measurement.voltage_reported(value / 10)
elif attrid == TUYA_DIN_SWITCH_ATTR:
self.endpoint.device.switch_bus.listener_event(
SWITCH_EVENT, self.endpoint.endpoint_id, value
)
class TuyaPowerMeasurement(LocalDataCluster, ElectricalMeasurement):
"""Custom class for power, voltage and current measurement."""
cluster_id = ElectricalMeasurement.cluster_id
POWER_ID = 0x050B
VOLTAGE_ID = 0x0505
CURRENT_ID = 0x0508
REACTIVE_POWER_ID = 0x050E
AC_FREQUENCY_ID = 0x0300
TOTAL_REACTIVE_POWER_ID = 0x0305
POWER_FACTOR_ID = 0x0510
AC_VOLTAGE_MULTIPLIER = 0x0600
AC_VOLTAGE_DIVISOR = 0x0601
AC_CURRENT_MULTIPLIER = 0x0602
AC_CURRENT_DIVISOR = 0x0603
AC_FREQUENCY_MULTIPLIER = 0x0400
AC_FREQUENCY_DIVISOR = 0x0401
_CONSTANT_ATTRIBUTES = {
AC_VOLTAGE_MULTIPLIER: 1,
AC_VOLTAGE_DIVISOR: 10,
AC_CURRENT_MULTIPLIER: 1,
AC_CURRENT_DIVISOR: 1000,
AC_FREQUENCY_MULTIPLIER: 1,
AC_FREQUENCY_DIVISOR: 100,
}
def voltage_reported(self, value):
"""Voltage reported."""
self._update_attribute(self.VOLTAGE_ID, value)
def power_reported(self, value):
"""Power reported."""
self._update_attribute(self.POWER_ID, value)
def power_factor_reported(self, value):
"""Power Factor reported."""
self._update_attribute(self.POWER_FACTOR_ID, value)
def reactive_power_reported(self, value):
"""Reactive Power reported."""
self._update_attribute(self.REACTIVE_POWER_ID, value)
def current_reported(self, value):
"""Ampers reported."""
self._update_attribute(self.CURRENT_ID, value)
def frequency_reported(self, value):
"""AC Frequency reported."""
self._update_attribute(self.AC_FREQUENCY_ID, value)
def reactive_energy_reported(self, value):
"""Summation Reactive Energy reported."""
self._update_attribute(self.TOTAL_REACTIVE_POWER_ID, value)
class TuyaElectricalMeasurement(LocalDataCluster, Metering):
"""Custom class for total energy measurement."""
cluster_id = Metering.cluster_id
CURRENT_DELIVERED_ID = 0x0000
CURRENT_RECEIVED_ID = 0x0001
#CURRENT_TIER1_DELIVERED_ID = 0x0100
POWER_WATT = 0x0000
"""Setting unit of measurement."""
_CONSTANT_ATTRIBUTES = {0x0300: POWER_WATT}
def energy_deliver_reported(self, value):
"""Summation Energy Deliver reported."""
self._update_attribute(self.CURRENT_DELIVERED_ID, value)
def energy_receive_reported(self, value):
"""Summation Energy Receive reported."""
self._update_attribute(self.CURRENT_RECEIVED_ID, value)
#def energy_tier1_deliver_reported(self, value):
# """Summation Energy Tier1 Receive reported."""
# self._update_attribute(self.CURRENT_TIER1_DELIVERED_ID, value)
class HikingManufClusterDinPower(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the Hiking Power Meter device."""
attributes = {
HIKING_DIN_SWITCH_ATTR: ("switch", t.uint8_t, True),
HIKING_TOTAL_ENERGY_DELIVERED_ATTR: ("energy_delivered", t.uint32_t, True),
HIKING_TOTAL_ENERGY_RECEIVED_ATTR: ("energy_received", t.uint16_t, True),
HIKING_VOLTAGE_CURRENT_ATTR: ("voltage_current", t.uint32_t, True),
HIKING_POWER_ATTR: ("power", t.uint16_t, True),
HIKING_FREQUENCY_ATTR: ("frequency", t.uint16_t, True),
HIKING_TOTAL_REACTIVE_ATTR: ("total_reactive_energy", t.int32s, True),
HIKING_REACTIVE_POWER_ATTR: ("reactive_power", t.int16s, True),
HIKING_POWER_FACTOR_ATTR: ("power_factor", t.uint16_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == HIKING_DIN_SWITCH_ATTR:
self.endpoint.device.switch_bus.listener_event(SWITCH_EVENT, 16, value)
elif attrid == HIKING_TOTAL_ENERGY_DELIVERED_ATTR:
self.endpoint.smartenergy_metering.energy_deliver_reported(value / 100)
elif attrid == HIKING_TOTAL_ENERGY_RECEIVED_ATTR:
self.endpoint.smartenergy_metering.energy_receive_reported(value / 100)
elif attrid == HIKING_VOLTAGE_CURRENT_ATTR:
self.endpoint.electrical_measurement.current_reported(value >> 16)
self.endpoint.electrical_measurement.voltage_reported(
(value & 0x0000FFFF) / 10
)
elif attrid == HIKING_POWER_ATTR:
self.endpoint.electrical_measurement.power_reported(value)
elif attrid == HIKING_FREQUENCY_ATTR:
self.endpoint.electrical_measurement.frequency_reported(value)
elif attrid == HIKING_TOTAL_REACTIVE_ATTR:
self.endpoint.electrical_measurement.reactive_energy_reported(value)
elif attrid == HIKING_REACTIVE_POWER_ATTR:
self.endpoint.electrical_measurement.reactive_power_reported(value)
elif attrid == HIKING_POWER_FACTOR_ATTR:
self.endpoint.electrical_measurement.power_factor_reported(value / 10)
class MatSeeManufClusterDinPower(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the Hiking Power Meter device."""
_LOGGER.debug("PRUEBA MatSeeManufClusterDinPower")
attributes = {
HIKING_DIN_SWITCH_ATTR: ("switch", t.uint8_t, True),
MATSEE_DPID_REVERSE_ENERGY_TOTAL_A_ATTR: ("energy_delivered", t.uint32_t, True),
MATSEE_DPID_FORWARD_ENERGY_TOTAL_A_ATTR: ("energy_received", t.uint32_t, True),
MATSEE_DPID_REVERSE_ENERGY_TOTAL_B_ATTR: ("energy_delivered_b", t.uint32_t, True),
MATSEE_DPID_FORWARD_ENERGY_TOTAL_B_ATTR: ("energy_received_b", t.uint32_t, True),
MATSEE_DPID_VOLTAGE_A_ATTR: ("voltage_current", t.uint32_t, True),
MATSEE_DPID_POWER_ID_A_ATTR: ("power", t.uint32_t, True),
MATSEE_DPID_POWER_ID_B_ATTR: ("power_b", t.uint32_t, True),
MATSEE_DPID_POWER_FREQ_ATTR: ("frequency", t.uint32_t, True),
MATSEE_DPID_POWER_TOTAL_ID_ATTR: ("total_reactive_energy", t.int32s, True),
MATSEE_DPID_POWER_A_COEF_ATTR: ("reactive_power", t.uint32_t, True),
MATSEE_DPID_POWER_B_COEF_ATTR: ("reactive_power_b", t.uint32_t, True),
MATSEE_DPID_POWER_FACTOR_A_ATTR: ("power_factor", t.uint32_t, True),
MATSEE_DPID_POWER_FACTOR_B_ATTR: ("power_factor_b", t.uint32_t, True),
MATSEE_DPID_CURRENT_A_ATTR: ("current", t.uint32_t, True),
MATSEE_DPID_CURRENT_B_ATTR: ("current_b", t.uint32_t, True),
MATSEE_DPID_POWER_DIRECTION_ID_A_ATTR: ("power_direction", t.uint8_t, True),
MATSEE_DPID_POWER_DIRECTION_ID_B_ATTR: ("power_direction_b", t.uint8_t, True),
MATSEE_DPID_UPDATE_RATE_ATTR: ("update_rate", t.uint32_t, True),
MATSEE_DPID_VOLTAGE_A_COEF_ATTR: ("voltage_coef", t.uint32_t, True),
MATSEE_DPID_CURRENT_A_COEF_ATTR: ("current_coef", t.uint32_t, True),
MATSEE_DPID_CURRENT_B_COEF_ATTR: ("current_coef_b", t.uint32_t, True),
MATSEE_DPID_ENERGY_A_COEF_ATTR: ("energy_coef", t.uint32_t, True),
MATSEE_DPID_ENERGY_B_COEF_ATTR: ("energy_coef_b", t.uint32_t, True),
MATSEE_DPID_ENERGY_A_COEF_REV_ATTR: ("energy_coef_rev", t.uint32_t, True),
MATSEE_DPID_ENERGY_B_COEF_REV_ATTR: ("energy_coef_rev_b", t.uint32_t, True),
MATSEE_DPID_FREQ_COEF_ATTR: ("frequency_coef", t.uint32_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == HIKING_DIN_SWITCH_ATTR:
self.endpoint.device.switch_bus.listener_event(SWITCH_EVENT, 16, value)
elif attrid == MATSEE_DPID_REVERSE_ENERGY_TOTAL_A_ATTR:
self.endpoint.smartenergy_metering.energy_deliver_reported(value / 100)
elif attrid == MATSEE_DPID_FORWARD_ENERGY_TOTAL_A_ATTR:
self.endpoint.smartenergy_metering.energy_receive_reported(value / 100)
#elif attrid == MATSEE_DPID_REVERSE_ENERGY_TOTAL_B_ATTR:
# self.endpoint.smartenergy_metering.energy_tier1_deliver_reported(value / 100)
elif attrid == MATSEE_DPID_CURRENT_A_ATTR:
self.endpoint.electrical_measurement.current_reported(value)
#elif attrid == MATSEE_DPID_CURRENT_B_ATTR:
# self.endpoint.electrical_measurement.current_reported((value & 0x0000FFFF)/1000)
elif attrid == MATSEE_DPID_VOLTAGE_A_ATTR:
#self.endpoint.electrical_measurement.current_reported(value >> 16)
#self.endpoint.electrical_measurement.current_reported((value & 0x0000FFFF) / 10)
self.endpoint.electrical_measurement.voltage_reported(
value
)
elif attrid == MATSEE_DPID_POWER_ID_A_ATTR:
self.endpoint.electrical_measurement.power_reported(value)
elif attrid == MATSEE_DPID_POWER_FREQ_ATTR:
self.endpoint.electrical_measurement.frequency_reported(value)
elif attrid == MATSEE_DPID_POWER_TOTAL_ID_ATTR:
self.endpoint.electrical_measurement.reactive_energy_reported(value)
elif attrid == MATSEE_DPID_POWER_A_COEF_ATTR:
self.endpoint.electrical_measurement.reactive_power_reported(value)
elif attrid == MATSEE_DPID_POWER_FACTOR_A_ATTR:
self.endpoint.electrical_measurement.power_factor_reported(value / 100)
class TuyaPowerMeter(TuyaSwitch):
"""Tuya power meter device."""
def __init__(self, *args, **kwargs):
"""Init device."""
self.switch_bus = Bus()
super().__init__(*args, **kwargs)
signature = {
# "node_descriptor": "<NodeDescriptor byte1=1 byte2=64 mac_capability_flags=142 manufacturer_code=4098
# maximum_buffer_size=82 maximum_incoming_transfer_size=82 server_mask=11264
# maximum_outgoing_transfer_size=82 descriptor_capability_field=0>",
# device_version=1
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]
MODELS_INFO: [
("_TZE200_byzdayie", "TS0601"),
("_TZE200_ewxhg6o9", "TS0601"),
("_TZE204_81yrt3lo", "TS0601"),
],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=51
# device_version=1
# input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterDinPower,
TuyaPowerMeasurement,
TuyaElectricalMeasurement,
TuyaOnOff,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
}
}
class HikingPowerMeter(TuyaSwitch):
"""Hiking Power Meter Device - DDS238-2."""
signature = {
# "node_descriptor": "<NodeDescriptor byte1=1 byte2=64 mac_capability_flags=142 manufacturer_code=4098
# maximum_buffer_size=82 maximum_incoming_transfer_size=82 server_mask=11264
# maximum_outgoing_transfer_size=82 descriptor_capability_field=0>",
# device_version=1
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]
MODELS_INFO: [("_TZE200_bkkmqmyo", "TS0601")],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=51
# device_version=1
# input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
HikingManufClusterDinPower,
TuyaElectricalMeasurement,
TuyaPowerMeasurement,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
16: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
TuyaOnOff,
],
OUTPUT_CLUSTERS: [],
},
}
}
class TuyaPowerMeter_GPP(TuyaSwitch):
"""Tuya power meter device."""
def __init__(self, *args, **kwargs):
"""Init device."""
self.switch_bus = Bus()
super().__init__(*args, **kwargs)
signature = {
# "node_descriptor": "<NodeDescriptor byte1=1 byte2=64 mac_capability_flags=142 manufacturer_code=4098
# maximum_buffer_size=82 maximum_incoming_transfer_size=82 server_mask=11264
# maximum_outgoing_transfer_size=82 descriptor_capability_field=0>",
# device_version=1
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]
MODELS_INFO: [
("_TZE200_lsanae15", "TS0601"),
("_TZE204_81yrt3lo", "TS0601"),
],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=51
# device_version=1
# input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
242: {
# <SimpleDescriptor endpoint=242 profile=41440 device_type=97
# input_clusters=[]
# output_clusters=[33]
PROFILE_ID: 41440,
DEVICE_TYPE: 97,
INPUT_CLUSTERS: [],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
MatSeeManufClusterDinPower,
TuyaPowerMeasurement,
TuyaElectricalMeasurement,
TuyaOnOff,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
242: {
# <SimpleDescriptor endpoint=242 profile=41440 device_type=97
# input_clusters=[]
# output_clusters=[33]
PROFILE_ID: 41440,
DEVICE_TYPE: 97,
INPUT_CLUSTERS: [],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
}
}

View File

@@ -0,0 +1,293 @@
"""Tuya Din Power Meter."""
from zigpy.profiles import zha
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time
from zigpy.zcl.clusters.homeautomation import ElectricalMeasurement
from zigpy.zcl.clusters.smartenergy import Metering
from zhaquirks import Bus, LocalDataCluster
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.tuya import TuyaManufClusterAttributes, TuyaOnOff, TuyaSwitch
TUYA_TOTAL_ENERGY_ATTR = 0x0211
TUYA_CURRENT_ATTR = 0x0212
TUYA_POWER_ATTR = 0x0213
TUYA_VOLTAGE_ATTR = 0x0214
TUYA_DIN_SWITCH_ATTR = 0x0101
SWITCH_EVENT = "switch_event"
"""Hiking Power Meter Attributes"""
HIKING_DIN_SWITCH_ATTR = 0x0110
HIKING_TOTAL_ENERGY_DELIVERED_ATTR = 0x0201
HIKING_TOTAL_ENERGY_RECEIVED_ATTR = 0x0266
HIKING_VOLTAGE_CURRENT_ATTR = 0x0006
HIKING_POWER_ATTR = 0x0267
HIKING_FREQUENCY_ATTR = 0x0269
HIKING_POWER_FACTOR_ATTR = 0x026F
HIKING_TOTAL_REACTIVE_ATTR = 0x026D
HIKING_REACTIVE_POWER_ATTR = 0x026E
class TuyaManufClusterDinPower(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the Tuya Power Meter device."""
attributes = {
TUYA_TOTAL_ENERGY_ATTR: ("energy", t.uint32_t, True),
TUYA_CURRENT_ATTR: ("current", t.int16s, True),
TUYA_POWER_ATTR: ("power", t.uint16_t, True),
TUYA_VOLTAGE_ATTR: ("voltage", t.uint16_t, True),
TUYA_DIN_SWITCH_ATTR: ("switch", t.uint8_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == TUYA_TOTAL_ENERGY_ATTR:
self.endpoint.smartenergy_metering.energy_deliver_reported(value / 100)
elif attrid == TUYA_CURRENT_ATTR:
self.endpoint.electrical_measurement.current_reported(value)
elif attrid == TUYA_POWER_ATTR:
self.endpoint.electrical_measurement.power_reported(value / 10)
elif attrid == TUYA_VOLTAGE_ATTR:
self.endpoint.electrical_measurement.voltage_reported(value / 10)
elif attrid == TUYA_DIN_SWITCH_ATTR:
self.endpoint.device.switch_bus.listener_event(
SWITCH_EVENT, self.endpoint.endpoint_id, value
)
class TuyaPowerMeasurement(LocalDataCluster, ElectricalMeasurement):
"""Custom class for power, voltage and current measurement."""
POWER_ID = 0x050B
VOLTAGE_ID = 0x0505
CURRENT_ID = 0x0508
REACTIVE_POWER_ID = 0x050E
AC_FREQUENCY_ID = 0x0300
TOTAL_REACTIVE_POWER_ID = 0x0305
POWER_FACTOR_ID = 0x0510
AC_CURRENT_MULTIPLIER = 0x0602
AC_CURRENT_DIVISOR = 0x0603
AC_FREQUENCY_MULTIPLIER = 0x0400
AC_FREQUENCY_DIVISOR = 0x0401
_CONSTANT_ATTRIBUTES = {
AC_CURRENT_MULTIPLIER: 1,
AC_CURRENT_DIVISOR: 1000,
AC_FREQUENCY_MULTIPLIER: 1,
AC_FREQUENCY_DIVISOR: 100,
}
def voltage_reported(self, value):
"""Voltage reported."""
self._update_attribute(self.VOLTAGE_ID, value)
def power_reported(self, value):
"""Power reported."""
self._update_attribute(self.POWER_ID, value)
def power_factor_reported(self, value):
"""Power Factor reported."""
self._update_attribute(self.POWER_FACTOR_ID, value)
def reactive_power_reported(self, value):
"""Reactive Power reported."""
self._update_attribute(self.REACTIVE_POWER_ID, value)
def current_reported(self, value):
"""Ampers reported."""
self._update_attribute(self.CURRENT_ID, value)
def frequency_reported(self, value):
"""AC Frequency reported."""
self._update_attribute(self.AC_FREQUENCY_ID, value)
def reactive_energy_reported(self, value):
"""Summation Reactive Energy reported."""
self._update_attribute(self.TOTAL_REACTIVE_POWER_ID, value)
class TuyaElectricalMeasurement(LocalDataCluster, Metering):
"""Custom class for total energy measurement."""
CURRENT_DELIVERED_ID = 0x0000
CURRENT_RECEIVED_ID = 0x0001
POWER_WATT = 0x0000
"""Setting unit of measurement."""
_CONSTANT_ATTRIBUTES = {0x0300: POWER_WATT}
def energy_deliver_reported(self, value):
"""Summation Energy Deliver reported."""
self._update_attribute(self.CURRENT_DELIVERED_ID, value)
def energy_receive_reported(self, value):
"""Summation Energy Receive reported."""
self._update_attribute(self.CURRENT_RECEIVED_ID, value)
class HikingManufClusterDinPower(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the Hiking Power Meter device."""
attributes = {
HIKING_DIN_SWITCH_ATTR: ("switch", t.uint8_t, True),
HIKING_TOTAL_ENERGY_DELIVERED_ATTR: ("energy_delivered", t.uint32_t, True),
HIKING_TOTAL_ENERGY_RECEIVED_ATTR: ("energy_received", t.uint16_t, True),
HIKING_VOLTAGE_CURRENT_ATTR: ("voltage_current", t.uint32_t, True),
HIKING_POWER_ATTR: ("power", t.uint16_t, True),
HIKING_FREQUENCY_ATTR: ("frequency", t.uint16_t, True),
HIKING_TOTAL_REACTIVE_ATTR: ("total_reactive_energy", t.int32s, True),
HIKING_REACTIVE_POWER_ATTR: ("reactive_power", t.int16s, True),
HIKING_POWER_FACTOR_ATTR: ("power_factor", t.uint16_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == HIKING_DIN_SWITCH_ATTR:
self.endpoint.device.switch_bus.listener_event(SWITCH_EVENT, 16, value)
elif attrid == HIKING_TOTAL_ENERGY_DELIVERED_ATTR:
self.endpoint.smartenergy_metering.energy_deliver_reported(value / 100)
elif attrid == HIKING_TOTAL_ENERGY_RECEIVED_ATTR:
self.endpoint.smartenergy_metering.energy_receive_reported(value / 100)
elif attrid == HIKING_VOLTAGE_CURRENT_ATTR:
self.endpoint.electrical_measurement.current_reported(value >> 16)
self.endpoint.electrical_measurement.voltage_reported(
(value & 0x0000FFFF) / 10
)
elif attrid == HIKING_POWER_ATTR:
self.endpoint.electrical_measurement.power_reported(value)
elif attrid == HIKING_FREQUENCY_ATTR:
self.endpoint.electrical_measurement.frequency_reported(value)
elif attrid == HIKING_TOTAL_REACTIVE_ATTR:
self.endpoint.electrical_measurement.reactive_energy_reported(value)
elif attrid == HIKING_REACTIVE_POWER_ATTR:
self.endpoint.electrical_measurement.reactive_power_reported(value)
elif attrid == HIKING_POWER_FACTOR_ATTR:
self.endpoint.electrical_measurement.power_factor_reported(value / 10)
class TuyaPowerMeter(TuyaSwitch):
"""Tuya power meter device."""
def __init__(self, *args, **kwargs):
"""Init device."""
self.switch_bus = Bus()
super().__init__(*args, **kwargs)
signature = {
# "node_descriptor": "<NodeDescriptor byte1=1 byte2=64 mac_capability_flags=142 manufacturer_code=4098
# maximum_buffer_size=82 maximum_incoming_transfer_size=82 server_mask=11264
# maximum_outgoing_transfer_size=82 descriptor_capability_field=0>",
# device_version=1
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]
MODELS_INFO: [
("_TZE200_byzdayie", "TS0601"),
("_TZE200_ewxhg6o9", "TS0601"),
],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=51
# device_version=1
# input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterDinPower,
TuyaPowerMeasurement,
TuyaElectricalMeasurement,
TuyaOnOff,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
}
}
class HikingPowerMeter(TuyaSwitch):
"""Hiking Power Meter Device - DDS238-2."""
signature = {
# "node_descriptor": "<NodeDescriptor byte1=1 byte2=64 mac_capability_flags=142 manufacturer_code=4098
# maximum_buffer_size=82 maximum_incoming_transfer_size=82 server_mask=11264
# maximum_outgoing_transfer_size=82 descriptor_capability_field=0>",
# device_version=1
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]
MODELS_INFO: [
("_TZE200_bkkmqmyo", "TS0601"),
("_TZE204_81yrt3lo", "TS0601"),
],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=51
# device_version=1
# input_clusters=[0, 4, 5, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
HikingManufClusterDinPower,
TuyaElectricalMeasurement,
TuyaPowerMeasurement,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
16: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
TuyaOnOff,
],
OUTPUT_CLUSTERS: [],
},
}
}

View File

@@ -0,0 +1,120 @@
"""Smoke Sensor."""
import logging
import zigpy.profiles.zha
from zigpy.quirks import CustomCluster, CustomDevice
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time
from zigpy.zcl.clusters.security import IasZone
from zhaquirks import Bus
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
ZONE_STATUS,
ZONE_TYPE,
)
from zhaquirks.tuya import TuyaManufCluster, TuyaManufClusterAttributes
_LOGGER = logging.getLogger(__name__)
TUYA_SMOKE_DETECTED_ATTR = 0x0401 # [0]/[1] [Detected]/[Clear]!
class TuyaSmokeDetectorCluster(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of the TS0601 smoke detector."""
attributes = {
TUYA_SMOKE_DETECTED_ATTR: ("smoke_detected", t.uint8_t, True),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid == TUYA_SMOKE_DETECTED_ATTR:
if value == 0:
self.endpoint.device.ias_bus.listener_event(
"update_zone_status", IasZone.ZoneStatus.Alarm_1
)
else:
self.endpoint.device.ias_bus.listener_event("update_zone_status", 0)
else:
_LOGGER.warning(
"[0x%04x:%s:0x%04x] unhandled attribute: 0x%04x",
self.endpoint.device.nwk,
self.endpoint.endpoint_id,
self.cluster_id,
attrid,
)
class TuyaIasZone(CustomCluster, IasZone):
"""IAS Zone."""
_CONSTANT_ATTRIBUTES = {ZONE_TYPE: IasZone.ZoneType.Fire_Sensor}
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
self.endpoint.device.ias_bus.add_listener(self)
def update_zone_status(self, value):
"""Update IAS status."""
super()._update_attribute(ZONE_STATUS, value)
class TuyaSmokeDetector0601(CustomDevice):
"""TS0601 Smoke detector quirk."""
def __init__(self, *args, **kwargs):
"""Init."""
self.ias_bus = Bus()
super().__init__(*args, **kwargs)
signature = {
MODELS_INFO: [
("_TZE200_aycxwiau", "TS0601"),
("_TZE200_ntcy3xu1", "TS0601"),
("_TZE200_vzekyi4c", "TS0601"),
("_TZE200_uebojraa", "TS0601"),
],
ENDPOINTS: {
1: {
PROFILE_ID: zigpy.profiles.zha.PROFILE_ID,
DEVICE_TYPE: zigpy.profiles.zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [
Time.cluster_id,
Ota.cluster_id,
],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zigpy.profiles.zha.PROFILE_ID,
DEVICE_TYPE: zigpy.profiles.zha.DeviceType.IAS_ZONE,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaIasZone,
TuyaSmokeDetectorCluster,
],
OUTPUT_CLUSTERS: [
Time.cluster_id,
Ota.cluster_id,
],
},
},
}

View File

@@ -0,0 +1,244 @@
############################################
#############################################
# ATHOM 15W RGBWW Bulb Flasher
#
# # V1.0 2025-02-15 Initial Version
#
# Device https://www.athom.tech/blank-1/15w-color-bulb
#
# DESCRIPTION
# Starts up and flashes a RGBWW lightbulb a white colour
# On and off time (duty cycle) is configurable
# Colour Temp (in K) is configurable
# There is no fading between transitions
#
#############################################
#############################################
#############################################
# USER VARIABLE SUBSTITUTIONS
# Give the device a useful name & description here
# and change values accordingly.
#############################################
substitutions:
devicename: esp-athombulbflasher
friendly_name: "Flasher for Athom 15W Bulb"
description_comment: "Athom RGBWW light bulb that will flash on boot and allow colour temp & duty cycle adjustment"
# Adjust the color temperature here (200 mired is approx 5000k
white_temp: "3000K"
# Adjust the ON/OFF times for flashing.
# 600ms on, 400ms off => 60% ON, 40% OFF duty cycle
on_time_ms: "500ms"
off_time_ms: "500ms"
#############################################
# OTHER VARIABLE SUBSTITUTIONS
# Give the device a useful name & description here
# and change values accordingly.
#############################################
# If NOT using a secrets file, just replace these with the passwords etc (in quotes)
api_key: !secret esp-athombulbflasher_api_key # unfortunately you can't use substitutions inside secrets names
ota_pass: !secret esp-athombulbflasher_ota_pass # unfortunately you can't use substitutions inside secrets names
wifi_ssid: !secret wifi_ssid
wifi_password: !secret wifi_password
fallback_ap_password: !secret fallback_ap_password
# Add these if we are giving it a static ip, or remove them in the Wifi section
#static_ip_address: !secret esp-athombulbflasher_static_ip
#static_ip_gateway: !secret esp-athombulbflasher_gateway
#static_ip_subnet: !secret esp-athombulbflasher_subnet
#mqtt_server: !secret mqtt_server
#mqtt_username: !secret mqtt_username
#mqtt_password: !secret mqtt_password
#mqtt_topic: "esphome" #main topic for the mqtt server, call it what you like
# Add these if we are using the internal web server (this is pretty processor intensive)
#web_server_username: !secret web_server_username
#web_server_password: !secret web_server_password
#update_interval: 60s # update time for for general sensors etc
#############################################
# ESP Platform and Framework
# https://esphome.io/components/esp32.html
#############################################
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
comment: ${description_comment} # appears on the esphome page in HA
on_boot:
priority: 800
then:
- light.turn_on:
id: my_light
effect: "Flashing White"
#############################################
# ESP Platform and Framework
# https://esphome.io/components/esp32.html
#############################################
esp8266:
board: esp01_1m
#############################################
# ESPHome Logging Enable
# https://esphome.io/components/logger.html
#############################################
logger:
level: INFO # INFO Level suggested, or DEBUG for testing
#baud_rate: 0 # set to 0 for no logging via UART, needed if you are using it for other serial things (eg PZEM)
#esp8266_store_log_strings_in_flash: false
#tx_buffer_size: 64
#############################################
# Enable the Home Assistant API
# https://esphome.io/components/api.html
#############################################
api:
encryption:
key: ${api_key}
#############################################
# Enable Over the Air Update Capability
# https://esphome.io/components/ota.html?highlight=ota
#############################################
ota:
- platform: esphome
password: ${ota_pass}
#############################################
# Safe Mode
# Safe mode will detect boot loops
# https://esphome.io/components/safe_mode
#############################################
safe_mode:
#############################################
# Wifi Settings
# https://esphome.io/components/wifi.html
#
# Power Save mode (can reduce wifi reliability)
# NONE (least power saving, Default for ESP8266)
# LIGHT (Default for ESP32)
# HIGH (most power saving)
#############################################
wifi:
ssid: ${wifi_ssid}
password: ${wifi_password}
#power_save_mode: LIGHT # https://esphome.io/components/wifi.html#wifi-power-save-mode
#manual_ip: # optional static IP address
#static_ip: ${static_ip_address}
#gateway: ${static_ip_gateway}
#subnet: ${static_ip_subnet}
ap: # Details for fallback hotspot in case wifi connection fails https://esphome.io/components/wifi.html#access-point-mode
ssid: ${devicename} AP
password: ${fallback_ap_password}
ap_timeout: 30min # Time until it brings up fallback AP. default is 1min
captive_portal: # extra fallback mechanism for when connecting if the configured WiFi fails
#############################################
# MQTT Monitoring
# https://esphome.io/components/mqtt.html?highlight=mqtt
# MUST also have api enabled if you enable MQTT
#############################################
#mqtt:
#broker: ${mqtt_server}
#topic_prefix: ${mqtt_topic}/${devicename}
#username: ${mqtt_username}
#password: ${mqtt_password}
##discovery: True # enable entity discovery (true is default)
##discover_ip: True # enable device discovery (true is default)
#############################################
# Web Portal for display and monitoring
# Turning this off is probably a good idea to save resources.
# https://esphome.io/components/web_server.html
#############################################
#web_server:
# port: 80
# auth:
# username: ${web_server_username} # probably a good idea to secure it
# password: ${web_server_password}
# ---------------------------------------------------------
# OUTPUTS: 5 x PWM channels for the Athom 15W RGBWW bulb
# ---------------------------------------------------------
output:
- platform: esp8266_pwm
id: output_red
pin: GPIO4
frequency: 1000 Hz
- platform: esp8266_pwm
id: output_green
pin: GPIO5
frequency: 1000 Hz
- platform: esp8266_pwm
id: output_blue
pin: GPIO12
frequency: 1000 Hz
# Typically one channel is cold white...
- platform: esp8266_pwm
id: output_cold_white
pin: GPIO14
frequency: 1000 Hz
# ...and one channel is warm white (inverted on GPIO13).
- platform: esp8266_pwm
id: output_warm_white
pin: GPIO13
frequency: 1000 Hz
inverted: true
# ---------------------------------------------------------
# LIGHT COMPONENT: RGBWW + a strobe effect for flashing
# ---------------------------------------------------------
light:
- platform: rgbww
name: ${friendly_name}
id: my_light
red: output_red
green: output_green
blue: output_blue
cold_white: output_cold_white
warm_white: output_warm_white
# Typical white temperature mapping for RGBWW
cold_white_color_temperature: 6500 K
warm_white_color_temperature: 2700 K
# Ensure it always powers on (and with our desired effect).
restore_mode: ALWAYS_ON
# You can omit this or set it to zero for no fade on effect changes.
default_transition_length: 0s
# The custom strobe effect for flashing white
effects:
- strobe:
name: "Flashing White"
colors:
# Note the Kelvin value is replaced at compile time:
- state: True
brightness: 100%
color_temperature: "${white_temp}"
duration: ${on_time_ms}
- state: False
brightness: 0%
color_temperature: "${white_temp}"
duration: ${off_time_ms}

View File

@@ -1,6 +1,6 @@
#############################################
#############################################
# BYD ATTO3 12V Battery Monitor
# Nissan Leaf 12V Battery Monitor
# Monitoring the status of a vehicle 12V battery with
# an esp8266 (D1 Mini). It will obviously only
# transmit when the vehicle is within wifi range.

View File

@@ -0,0 +1,629 @@
#############################################
#############################################
# MASTER BATHROOM HEATED TOWEL RAIL
# Controlled by a Sonoff Basic
#
# V1.0 2025-02-14 Initial Version
#
# INSTRUCTIONS
# - It allows a heated towel rail device to work in a standalone operation
# - On startup, it will turn on for 2 hours then go into timer mode (this allows you to just turn it on to get some heat immediately)
# - The timer has a morning and evening time (but no weekday/weekend setting)
# - Default values are 5am-7am and 9pm-Midnight (as this suits our use case)
# - It uses SNTP for time setting (but obviously only if wifi & networking are working)
# - It will default to an internal timer if no wifi. To reset internal timer, reboot the device at 12pm (noon)
# - If on a network and there is a MQTT server, you can set the 4 on/off times via MQTT (See below commands)
# - You can set 4 modes ON/OFF/TIMER/STARTUP via MQTT
# - Any new timer times set via MQTT will be remembered though a reboot
# - On a reboot, the device will always turn on for the Startup Duration (STARTUP mode, default 2 hours)
# - TIMER mode will always be switched on after startup mode is complete
# - If you need it ON continuously with no MQTT, toggle power ON/OFF 4 times within 20 seconds (with ~2 secs in between to allow it to boot)
#
# MQTT Commands
# Values will be set in place on the update_interval time, not immediately
# Use 00:00 in 24hr format for time setting. Note there is no weekday/weekend setting
# mqtt_timer_topic/morning-on/06:00 : Time towel rail will go on
# mqtt_timer_topic/morning-off/08:00 : Time towel rail will go off
# mqtt_timer_topic/evening-on/09:00 : Time towel rail will go on
# mqtt_timer_topic/evening-off/00:00 : Time towel rail will go off
# mqtt_timer_topic/operation/ON : Towel rail permanently on
# mqtt_timer_topic/operation/OFF : Towel rail permanently off
# mqtt_timer_topic/operation/TIMER : Towel rail will obey timer settings
# mqtt_timer_topic/operation/STARTUP : Turn on for 2 hours then TIMER (also on startup)
#
#############################################
#############################################
#############################################
# VARIABLE SUBSTITUTIONS
# Give the device a useful name & description here
# and change values accordingly.
#############################################
substitutions:
mqtt_timer_topic: "viewroad-commands/masterbath-towelrail" # Topics you will use to change stuff
startup_duration: "120" # Minutes to stay ON in STARTUP mode before reverting to TIMER
timezone: "Pacific/Auckland" # For setting clock with snmp
devicename: "esp-masterbathtowelrail"
friendly_name: "Master Bathroom Towelrail"
description_comment: "Sonoff Basic controlling ON/OFF/Timer for the Heated Towel Rail in the Master Bathroom"
# If NOT using a secrets file, just replace these with the passwords etc (in quotes)
api_key: !secret esp-masterbathtowelrail_api_key # unfortunately you can't use substitutions inside secrets names
ota_pass: !secret esp-masterbathtowelrail_ota_pass # unfortunately you can't use substitutions inside secrets names
wifi_ssid: !secret wifi_ssid
wifi_password: !secret wifi_password
fallback_ap_password: !secret fallback_ap_password
# Add these if we are giving it a static ip, or remove them in the Wifi section
#static_ip_address: !secret esp-occupancyoffice_static_ip
#static_ip_gateway: !secret esp-occupancyoffice_gateway
#static_ip_subnet: !secret esp-occupancyoffice_subnet
mqtt_server: !secret mqtt_server
mqtt_username: !secret mqtt_username
mqtt_password: !secret mqtt_password
mqtt_topic: "esphome" #main topic for the mqtt server, call it what you like
# Add these if we are using the internal web server (this is pretty processor intensive)
#web_server_username: !secret web_server_username
#web_server_password: !secret web_server_password
update_interval: 60s # update time for for general sensors etc
#############################################
# ESPHome
# https://esphome.io/components/esphome.html
#############################################
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
comment: ${description_comment} #a ppears on the esphome page in HA
on_boot:
priority: 900 # high priority to run after globals are initialized
then:
- lambda: |-
// 1) Figure out the current time in "seconds from midnight"
// using SNTP if available, otherwise fallback_time * 60.
bool have_sntp = id(sntp_time).now().is_valid();
int current_time_s = 0;
if (have_sntp) {
auto now = id(sntp_time).now();
current_time_s = now.hour * 3600 + now.minute * 60 + now.second;
} else {
// fallback_time is in minutes; convert to seconds
current_time_s = id(fallback_time) * 60;
}
// 2) Compare with the last boot time
int diff = current_time_s - id(last_boot_time_s);
// If within 20 seconds, increment boot_count; otherwise reset to 1
if (diff >= 0 && diff <= 20) {
id(boot_count)++;
} else {
id(boot_count) = 1;
}
// Update stored last boot time
id(last_boot_time_s) = current_time_s;
// 3) If we've booted 4+ times in 20s => force ON mode
if (id(boot_count) >= 4) {
id(operation_mode) = 1; // ON
ESP_LOGI("power_cycle", "Detected 4 power cycles in 20s => Forcing ON mode");
} else {
// Otherwise do your normal startup logic:
id(operation_mode) = 3; // on_boot -> sets operation_mode = 3 (STARTUP)
id(startup_timer) = 0; // and reset startup_timer = 0 (for time sync if no sntp)
ESP_LOGI("power_cycle", "Boot count=%d => STARTUP mode", id(boot_count));
}
#############################################
# ESP Platform and Framework
# https://esphome.io/components/esp32.html
#############################################
esp8266:
board: esp01_1m # The original sonoff basic
#############################################
# ESPHome Logging Enable
# https://esphome.io/components/logger.html
#############################################
logger:
level: INFO #INFO Level suggested, or DEBUG for testing
#baud_rate: 0 #set to 0 for no logging via UART, needed if you are using it for other serial things (eg PZEM)
#esp8266_store_log_strings_in_flash: false
#tx_buffer_size: 64
#############################################
# Enable the Home Assistant API
# https://esphome.io/components/api.html
#############################################
api:
encryption:
key: ${api_key}
#############################################
# Enable Over the Air Update Capability
# https://esphome.io/components/ota.html?highlight=ota
#############################################
ota:
- platform: esphome
password: ${ota_pass}
#############################################
# Safe Mode
# Safe mode will detect boot loops
# https://esphome.io/components/safe_mode
#############################################
safe_mode:
#############################################
# Wifi Settings
# https://esphome.io/components/wifi.html
#
# Power Save mode (can reduce wifi reliability)
# NONE (least power saving, Default for ESP8266)
# LIGHT (Default for ESP32)
# HIGH (most power saving)
#############################################
wifi:
ssid: ${wifi_ssid}
password: ${wifi_password}
#power_save_mode: LIGHT # https://esphome.io/components/wifi.html#wifi-power-save-mode
#manual_ip: # optional static IP address
#static_ip: ${static_ip_address}
#gateway: ${static_ip_gateway}
#subnet: ${static_ip_subnet}
ap: # Details for fallback hotspot in case wifi connection fails https://esphome.io/components/wifi.html#access-point-mode
ssid: ${devicename} AP
password: ${fallback_ap_password}
ap_timeout: 30min # Time until it brings up fallback AP. default is 1min
captive_portal: # extra fallback mechanism for when connecting if the configured WiFi fails
#############################################
# Real time clock time source for ESPHome
# If it's invalid, we fall back to an internal clock
# https://esphome.io/components/time/index.html
# https://esphome.io/components/time/sntp
#############################################
time:
- platform: sntp
id: sntp_time
#############################################
# MQTT Monitoring
# https://esphome.io/components/mqtt.html?highlight=mqtt
# MUST also have api enabled if you enable MQTT
#############################################
mqtt:
broker: ${mqtt_server}
topic_prefix: ${mqtt_topic}/${devicename}
username: ${mqtt_username}
password: ${mqtt_password}
#discovery: True # enable entity discovery (true is default)
#discover_ip: True # enable device discovery (true is default)
#############################################
# Global Variables for use in automations etc
# https://esphome.io/guides/automations.html?highlight=globals#global-variables
#############################################
globals:
# Tracks the time (in seconds from midnight) at the previous boot
- id: last_boot_time_s
type: int
restore_value: true
initial_value: "0"
# Counts how many consecutive boots have occurred within 10 seconds
- id: boot_count
type: int
restore_value: true
initial_value: "0"
# Morning On time (minutes from midnight),
# default 05:00 => 300
- id: morning_on
type: int
restore_value: true
initial_value: "300"
# Morning Off time (minutes from midnight),
# default 07:00 => 420
- id: morning_off
type: int
restore_value: true
initial_value: "420"
# Evening On time (minutes from midnight),
# default 21:00 => 1260
- id: evening_on
type: int
restore_value: true
initial_value: "1260"
# Evening Off time (minutes from midnight),
# default 00:00 => 0 => treat as midnight
- id: evening_off
type: int
restore_value: true
initial_value: "0"
####################################################
# operation_mode:
# 0 = OFF
# 1 = ON
# 2 = TIMER
# 3 = STARTUP
####################################################
- id: operation_mode
type: int
restore_value: false
initial_value: "3"
####################################################
# fallback_time is used if SNTP is invalid.
# We assume user powers on the device at 12:00 noon
# => 12 * 60 = 720 minutes from midnight.
# Not restored, so it resets each boot.
####################################################
- id: fallback_time
type: int
restore_value: false
initial_value: "720"
####################################################
# startup_timer: counts minutes in STARTUP mode
# After 'startup_duration' minutes, revert to TIMER.
# Not restored, so each boot starts fresh at 0.
####################################################
- id: startup_timer
type: int
restore_value: false
initial_value: "0"
#############################################
# Text Sensors
# https://esphome.io/components/text_sensor/index.html
#############################################
text_sensor:
############################
# MQTT Subscriptions
############################
####################################################
# Subscribe to the Morning On time, format "HH:MM"
# We check x.size() == 5 and x[2] == ':',
# then parse x.substr(0,2) and x.substr(3,2)
# std::string uses 'substr', not 'substring'.
####################################################
- platform: mqtt_subscribe
name: "Morning On Time"
id: morning_on_topic
topic: "${mqtt_timer_topic}/morning-on"
internal: True
on_value:
then:
- lambda: |-
// Expect "HH:MM" => total length = 5, with ':'
if (x.size() == 5 && x[2] == ':') {
int hour = atoi(x.substr(0, 2).c_str()); // "HH"
int minute = atoi(x.substr(3, 2).c_str()); // "MM"
id(morning_on) = hour * 60 + minute;
ESP_LOGI("timer","Received new Morning On: %02d:%02d", hour, minute);
} else {
ESP_LOGW("timer","Invalid Morning On format: %s", x.c_str());
}
####################################################
# Morning Off time => "HH:MM"
####################################################
- platform: mqtt_subscribe
name: "Morning Off Time"
id: morning_off_topic
topic: "${mqtt_timer_topic}/morning-off"
internal: True # No need to show this in Home Assistant as there is a sensor that shows the set value
on_value:
then:
- lambda: |-
if (x.size() == 5 && x[2] == ':') {
int hour = atoi(x.substr(0, 2).c_str());
int minute = atoi(x.substr(3, 2).c_str());
id(morning_off) = hour * 60 + minute;
ESP_LOGI("timer","Received new Morning Off: %02d:%02d", hour, minute);
} else {
ESP_LOGW("timer","Invalid Morning Off format: %s", x.c_str());
}
####################################################
# Evening On time => "HH:MM"
####################################################
- platform: mqtt_subscribe
name: "Evening On Time"
id: evening_on_topic
topic: "${mqtt_timer_topic}/evening-on"
internal: True # No need to show this in Home Assistant as there is a sensor that shows the set value
on_value:
then:
- lambda: |-
if (x.size() == 5 && x[2] == ':') {
int hour = atoi(x.substr(0, 2).c_str());
int minute = atoi(x.substr(3, 2).c_str());
id(evening_on) = hour * 60 + minute;
ESP_LOGI("timer","Received new Evening On: %02d:%02d", hour, minute);
} else {
ESP_LOGW("timer","Invalid Evening On format: %s", x.c_str());
}
####################################################
# Evening Off time => "HH:MM"
####################################################
- platform: mqtt_subscribe
name: "Evening Off Time"
id: evening_off_topic
topic: "${mqtt_timer_topic}/evening-off"
internal: True # No need to show this in Home Assistant as there is a sensor that shows the set value
on_value:
then:
- lambda: |-
if (x.size() == 5 && x[2] == ':') {
int hour = atoi(x.substr(0, 2).c_str());
int minute = atoi(x.substr(3, 2).c_str());
id(evening_off) = hour * 60 + minute;
ESP_LOGI("timer","Received new Evening Off: %02d:%02d", hour, minute);
} else {
ESP_LOGW("timer","Invalid Evening Off format: %s", x.c_str());
}
####################################################
# Subscribe to operation mode:
# OFF, ON, TIMER, STARTUP
# We do case-insensitive compare using strcasecmp
# (Requires <strings.h> typically included in ESPHome)
####################################################
- platform: mqtt_subscribe
name: "Timer Operation Mode"
id: timer_operation_mode_topic
topic: "${mqtt_timer_topic}/operation"
internal: True # No need to show this in Home Assistant as there is a sensor that shows the set value
on_value:
then:
- lambda: |-
/*
* In standard C++ (ESPHome), no 'equalsIgnoreCase()'.
* We use 'strcasecmp' for case-insensitive compare.
* Returns 0 if they match ignoring case.
*/
if (strcasecmp(x.c_str(), "TIMER") == 0) {
id(operation_mode) = 2;
ESP_LOGI("timer","Operation mode set to TIMER");
} else if (strcasecmp(x.c_str(), "ON") == 0) {
id(operation_mode) = 1;
ESP_LOGI("timer","Operation mode set to ON");
} else if (strcasecmp(x.c_str(), "OFF") == 0) {
id(operation_mode) = 0;
ESP_LOGI("timer","Operation mode set to OFF");
} else if (strcasecmp(x.c_str(), "STARTUP") == 0) {
id(operation_mode) = 3;
id(startup_timer) = 0;
ESP_LOGI("timer","Operation mode set to STARTUP");
} else {
ESP_LOGW("timer","Invalid operation mode: %s", x.c_str());
}
######################################################
# Expose the current operation mode (OFF, ON, TIMER, STARTUP)
######################################################
- platform: template
name: "Operation Mode State"
lambda: |-
// 0=OFF, 1=ON, 2=TIMER, 3=STARTUP
switch (id(operation_mode)) {
case 0: return {"OFF"};
case 1: return {"ON"};
case 2: return {"TIMER"};
case 3: return {"STARTUP"};
default: return {"UNKNOWN"};
}
update_interval: ${update_interval}
######################################################
# Expose the "Morning On" time as a text (HH:MM)
######################################################
- platform: template
name: "Morning On Time State"
lambda: |-
int hour = id(morning_on) / 60;
int minute = id(morning_on) % 60;
// Increase to 16 for safety
char buff[16];
snprintf(buff, sizeof(buff), "%02d:%02d", hour, minute);
return { std::string(buff) };
update_interval: ${update_interval}
######################################################
# Expose the "Morning Off" time as a text (HH:MM)
######################################################
- platform: template
name: "Morning Off Time State"
lambda: |-
int hour = id(morning_off) / 60;
int minute = id(morning_off) % 60;
// Increase buffer size to 8 just to be safe
// Increase to 16 for safety
char buff[16];
snprintf(buff, sizeof(buff), "%02d:%02d", hour, minute);
return { std::string(buff) };
update_interval: ${update_interval}
######################################################
# Expose the "Evening On" time as a text (HH:MM)
######################################################
- platform: template
name: "Evening On Time State"
lambda: |-
int hour = id(evening_on) / 60;
int minute = id(evening_on) % 60;
// Increase buffer size to 8 just to be safe
// Increase to 16 for safety
char buff[16];
snprintf(buff, sizeof(buff), "%02d:%02d", hour, minute);
return { std::string(buff) };
update_interval: ${update_interval}
######################################################
# Expose the "Evening Off" time as a text (HH:MM)
######################################################
- platform: template
name: "Evening Off Time State"
lambda: |-
int hour = id(evening_off) / 60;
int minute = id(evening_off) % 60;
// Increase buffer size to 8 just to be safe
// Increase to 16 for safety
char buff[16];
snprintf(buff, sizeof(buff), "%02d:%02d", hour, minute);
return { std::string(buff) };
update_interval: ${update_interval}
######################################################
# ESPHome Info
######################################################
- platform: version
name: ${friendly_name} Version
- platform: wifi_info
ip_address:
name: ${friendly_name} IP Address
#############################################
# General Sensors
# https://esphome.io/components/sensor/index.html
#############################################
sensor:
- platform: uptime # Uptime for this device
name: ${friendly_name} Uptime
update_interval: ${update_interval}
- platform: wifi_signal # Wifi Strength
name: ${friendly_name} Wifi Signal
update_interval: ${update_interval}
####################################################
# Relay Switch (Sonoff Basic Relay on GPIO12)
####################################################
switch:
- platform: gpio
name: "Towel Rail Power"
pin: GPIO12
id: relay
restore_mode: RESTORE_DEFAULT_OFF
####################################################
# Check every minute to decide relay state
####################################################
interval:
- interval: ${update_interval}
then:
- lambda: |-
// operation_mode:
// 0 = OFF
// 1 = ON
// 2 = TIMER
// 3 = STARTUP
int mode = id(operation_mode);
//////////////////////////////////////////////////
// STARTUP MODE: Relay ON for 'startup_duration'
// minutes, then automatically revert to TIMER.
//////////////////////////////////////////////////
if (mode == 3) {
id(startup_timer)++;
// Compare with the substitution startup_duration
if (id(startup_timer) < (int) ${startup_duration}) {
// Still within the STARTUP period => turn relay on
id(relay).turn_on();
} else {
// After 'startup_duration' minutes => switch to TIMER
id(operation_mode) = 2;
}
// Skip the rest of the logic
return;
}
//////////////////////////////////////////////////
// OFF MODE => always off
//////////////////////////////////////////////////
if (mode == 0) {
id(relay).turn_off();
return;
}
//////////////////////////////////////////////////
// ON MODE => always on
//////////////////////////////////////////////////
if (mode == 1) {
id(relay).turn_on();
return;
}
//////////////////////////////////////////////////
// TIMER MODE => follow morning/evening schedule
// using SNTP if valid, else fallback_time
//////////////////////////////////////////////////
if (mode == 2) {
auto now = id(sntp_time).now();
bool have_sntp = now.is_valid();
int current_mins;
if (!have_sntp) {
// SNTP not available => fallback clock
current_mins = id(fallback_time);
// increment the fallback clock by 1 minute
id(fallback_time) += 1;
// wrap around at 1440 => next day
if (id(fallback_time) >= 1440) {
id(fallback_time) = 0;
}
} else {
// Use real time from SNTP
current_mins = now.hour * 60 + now.minute;
}
bool should_on = false;
// If evening_off == 0 => treat as midnight => 1440
int evening_off_local = id(evening_off);
if (evening_off_local == 0) {
evening_off_local = 1440;
}
// Check morning window
// Example: morning_on=360 => 06:00, morning_off=480 => 08:00
// If current_mins in [360..480), should_on = true
if (id(morning_on) < id(morning_off)) {
if (current_mins >= id(morning_on) && current_mins < id(morning_off)) {
should_on = true;
}
}
// Check evening window
// Example: evening_on=540 => 09:00, evening_off=1440 => midnight
if (id(evening_on) < evening_off_local) {
if (current_mins >= id(evening_on) && current_mins < evening_off_local) {
should_on = true;
}
}
// Final relay state based on schedule
if (should_on) {
id(relay).turn_on();
} else {
id(relay).turn_off();
}
}

View File

@@ -1,488 +0,0 @@
#############################################
#############################################
#
#
#############################################
#############################################
#############################################
# Variable Substitutions
# Give the device a useful name & description here
# and change values accordingly.
#############################################
substitutions:
devicename: "esp-entmulti"
friendly_name: "Outside Entrance Multisensor"
description_comment: "D1 Mini ESP32 outside entranceway with, mmWave presence, PIR and more"
#if NOT using a secrets file, just replace these with the passwords etc (in quotes)
api_key: !secret esp-entmulti_api_key #unfortunately you can't use substitutions in secrets names
ota_pass: !secret esp-entmulti_ota_pass #unfortunately you can't use substitutions in secrets names
wifi_ssid: !secret wifi_ssid
wifi_password: !secret wifi_password
fallback_ap_password: !secret fallback_ap_password
#Add these if we are giving it a static ip, or remove them in the Wifi section
#static_ip_address: !secret esp-entmulti_static_ip
#static_ip_gateway: !secret esp-entmulti_gateway
#static_ip_subnet: !secret esp-entmulti_subnet
mqtt_server: !secret mqtt_server
mqtt_username: !secret mqtt_username
mqtt_password: !secret mqtt_password
mqtt_topic: "esphome" #main topic for the mqtt server, call it what you like
#web_server_username: !secret web_server_username
#web_server_password: !secret web_server_password
update_time: 30s #update time for for general temp sensors etc
#############################################
# ESPHome
# https://esphome.io/components/esphome.html
#############################################
esphome:
name: ${devicename}
friendly_name: ${friendly_name}
comment: ${description_comment} #appears on the esphome page in HA
min_version: 2024.6.0
#############################################
# ESP Platform and Framework
# https://esphome.io/components/esp32.html
#############################################
esp32:
board: esp32dev
framework:
#type: arduino
type: esp-idf #Suggested Use ESP-IDF Framework, or Plug Out the UART Cable Might Cause ESP32 Hang.
version: recommended #recommended, latest or dev
#############################################
# ESPHome external or custom components to use
# https://esphome.io/components/external_components.html
# https://github.com/ssieb/esphome_components/tree/master/components/serial
#############################################
#external_components:
# - source:
# type: git
# url: https://github.com/ssieb/custom_components #Thanks for @ssieb components.
# components: [ serial ] #text_sensor that reads lines for a uart. Also, a sensor that reads single binary values from the uart.
#############################################
# ESPHome Logging Enable
# https://esphome.io/components/logger.html
#############################################
logger:
level: INFO #INFO Level suggested, or DEBUG for testing
#baud_rate: 0 #set to 0 for no logging via UART, needed if you are using it for other serial things (eg PZEM)
#esp8266_store_log_strings_in_flash: false
#tx_buffer_size: 64
#############################################
# Enable the Home Assistant API
# https://esphome.io/components/api.html
#############################################
api:
encryption:
key: ${api_key}
# on_client_connected:
# - esp32_ble_tracker.start_scan:
# continuous: true
# on_client_disconnected:
# - esp32_ble_tracker.stop_scan:
#############################################
# Enable Over the Air Update Capability
# https://esphome.io/components/ota.html?highlight=ota
#############################################
ota:
- platform: esphome
password: ${ota_pass}
#############################################
# Safe Mode
# Safe mode will detect boot loops
# https://esphome.io/components/safe_mode
#############################################
safe_mode:
#############################################
# Wifi Settings
# https://esphome.io/components/wifi.html
#
# Power Save mode (can reduce wifi reliability)
# NONE (least power saving, Default for ESP8266)
# LIGHT (Default for ESP32)
# HIGH (most power saving)
#############################################
wifi:
ssid: ${wifi_ssid}
password: ${wifi_password}
#power_save_mode: LIGHT #https://esphome.io/components/wifi.html#wifi-power-save-mode
#manual_ip: #optional static IP address
#static_ip: ${static_ip_address}
#gateway: ${static_ip_gateway}
#subnet: ${static_ip_subnet}
ap: #Details for fallback hotspot in case wifi connection fails https://esphome.io/components/wifi.html#access-point-mode
ssid: $devicename fallback AP
password: !secret fallback_ap_password
ap_timeout: 5min #Time until it brings up fallback AP. default is 1min
#############################################
# Web Portal for display and monitoring
# Turning this off is probably a good idea to save resources.
# https://esphome.io/components/web_server.html
#############################################
#web_server:
# port: 80
# auth:
# username: ${web_server_username} #probably a good idea to secure it
# password: ${web_server_password}
#############################################
# MQTT Monitoring
# https://esphome.io/components/mqtt.html?highlight=mqtt
# MUST also have api enabled if you enable MQTT
#############################################
mqtt:
broker: ${mqtt_server}
topic_prefix: ${mqtt_topic}/${devicename}
username: ${mqtt_username}
password: ${mqtt_password}
#############################################
# i2c bus
# https://esphome.io/components/i2c.html
# 10, 50, 100, 200, 800 are possible settings
# for frequency, 50kHz is default
#############################################
#i2c:
# sda: GPIO19
# scl: GPIO21
# scan: True #look for devices on boot up and report
#frequency: 100kHz
#############################################
# UART Serial
# hardware on EPS32, but software, and can be glitchy on ESP8266
# https://esphome.io/components/uart.html
#############################################
#uart:
# id: ld2410_uart
# rx_pin: GPIO16 #For ESP32, you can use any pin, Recommend Use UART_2, Don't use UART_0, It might Cause Boot Fail or System Hang
# tx_pin: GPIO17 #For ESP32, you can use any pin, Recommend Use UART_2, Don't use UART_0, It might Cause Boot Fail or System Hang
# baud_rate: 256000 # default for LD2410 is 25600, 8, 0, NONE
# data_bits: 8
# stop_bits: 1
# parity: NONE
#############################################
# Bluetooth
# https://esphome.io/components/bluetooth_proxy.html
# https://esphome.io/components/esp32_ble_tracker.html
# Remember that this takes a LOT of processing. On the
# ESP32, enable the IDF framework, and disable the
# Web server component. Changing to the IDF framework
# needs to be via cable not OTA to change the
# partition setup.
#############################################
#bluetooth_proxy:
# active: true
# cache_services: true
#
#esp32_ble_tracker:
# scan_parameters:
# active: true
# continuous: false
#############################################
# Global Variables for use in automations etc
# https://esphome.io/guides/automations.html?highlight=globals#global-variables
#############################################
#############################################
# General esp status LED
# https://esphome.io/components/status_led.html
#############################################
status_led:
pin:
number: GPIO2 #ESP32 Onboard LED
ignore_strapping_warning: True #https://esphome.io/guides/faq.html#why-am-i-getting-a-warning-about-strapping-pins
inverted: false
#############################################
# Interval Automations
# https://esphome.io/guides/automations.html
#############################################
#############################################
# LD2410 Sensors
# https://esphome.io/components/sensor/ld2410.html
# https://www.hlktech.net/index.php?id=988
#############################################
#ld2410:
# uart_id: ld2410_uart
#############################################
# Number Sensors (custom component)
# refer https://github.com/ssieb/esphome_components/tree/master/components/serial
#############################################
#number:
# - platform: ld2410
# timeout:
# name: Timeout
# light_threshold:
# name: Light Threshold
# max_move_distance_gate:
# name: Max Move Distance Gate
# max_still_distance_gate:
# name: Max Still Distance Gate
# g0:
# move_threshold:
# name: g0 move threshold
# still_threshold:
# name: g0 still threshold
# g1:
# move_threshold:
# name: g1 move threshold
# still_threshold:
# name: g1 still threshold
# g2:
# move_threshold:
# name: g2 move threshold
# still_threshold:
# name: g2 still threshold
# g3:
# move_threshold:
# name: g3 move threshold
# still_threshold:
# name: g3 still threshold
# g4:
# move_threshold:
# name: g4 move threshold
# still_threshold:
# name: g4 still threshold
# g5:
# move_threshold:
# name: g5 move threshold
# still_threshold:
# name: g5 still threshold
# g6:
# move_threshold:
# name: g6 move threshold
# still_threshold:
# name: g6 still threshold
# g7:
# move_threshold:
# name: g7 move threshold
# still_threshold:
# name: g7 still threshold
# g8:
# move_threshold:
# name: g8 move threshold
# still_threshold:
# name: g8 still threshold
#The ld2410 select allows you to control your LD2410 Sensor.
#distance_resolution (Optional): Control the gates distance resolution. Can be 0.75m or 0.2m. Defaults to 0.75m. All options from Select.
#baud_rate (Optional): Control the serial port baud rate. Defaults to 256000. Once changed, all sensors will stop working until a fresh install with an updated UART Component configuration. All options from Select.
#light_function (Optional): If set, will affect the OUT pin value, based on light threshold. Can be off, low or above. Defaults to off. All options from Select.
#out_pin_level (Optional): Control OUT pin away value. Can be low or high. Defaults to low. All options from Select.
#ld2410_id (Optional, ID): Manually specify the ID for the LD2410 Sensor component if you are using multiple components.
#select:
# - platform: ld2410
# distance_resolution:
# name: ${friendly_name} LD2140 Distance Resolution
# baud_rate:
# name: ${friendly_name} LD2140 Baud Rate
# light_function:
# name: ${friendly_name} LD2140 Light Function
# out_pin_level:
# name: ${friendly_name} LD2140 Out Pin Level
#############################################
# General Sensors
# https://esphome.io/components/sensor/index.html
#############################################
sensor:
# - platform: bme280_i2c
# address: 0x76
# update_interval: ${update_time}
# temperature:
# name: ${friendly_name} BME280 Temp
# accuracy_decimals: 1
# oversampling: 2x
# pressure:
# name: ${friendly_name} BME280 Pressure
# oversampling: 2x
# humidity:
# name: ${friendly_name} BME280 Humidity
# accuracy_decimals: 1
# oversampling: 2x
################################
# WIFI SIGNAL
# Quality of Wifi in dBm
# https://esphome.io/components/sensor/wifi_signal.html
################################
- platform: wifi_signal
name: ${friendly_name} WiFi Signal
update_interval: 20s
#retain: true #retain useful if sleeping
- platform: uptime
name: ${friendly_name} Uptime
update_interval: 20s
#The ld2410 sensor values
# - platform: ld2410
# light:
# name: Light
# moving_distance:
# name : Moving Distance
# still_distance:
# name: Still Distance
# moving_energy:
# name: Move Energy
# still_energy:
# name: Still Energy
# detection_distance:
# name: Detection Distance
# g0:
# move_energy:
# name: g0 move energy
# still_energy:
# name: g0 still energy
# g1:
# move_energy:
# name: g1 move energy
# still_energy:
# name: g1 still energy
# g2:
# move_energy:
# name: g2 move energy
# still_energy:
# name: g2 still energy
# g3:
# move_energy:
# name: g3 move energy
# still_energy:
# name: g3 still energy
# g4:
# move_energy:
# name: g4 move energy
# still_energy:
# name: g4 still energy
# g5:
# move_energy:
# name: g5 move energy
# still_energy:
# name: g5 still energy
# g6:
# move_energy:
# name: g6 move energy
# still_energy:
# name: g6 still energy
# g7:
# move_energy:
# name: g7 move energy
# still_energy:
# name: g7 still energy
# g8:
# move_energy:
# name: g8 move energy
# still_energy:
# name: g8 still energy
# The ld2410 switch allows you to control your LD2410 Sensor.
#Bluetooth switch is only useful of you have a B or C model
#switch:
# - platform: ld2410
# engineering_mode:
# name: ${friendly_name} LD2140 Engineering Mode
#bluetooth:
#name: ${friendly_name} LD2140 Control Bluetooth
#The ld2410 button allows resetting
#button:
# - platform: ld2410
# factory_reset:
# name: ${friendly_name} LD2140 Factory reset"
# restart:
# name: ${friendly_name} LD2140 Restart
## query_params:
# name: Query Parameters
#############################################
# Text Sensors
# refer https://esphome.io/components/text_sensor/index.html
#############################################
#The ld2410 text sensor allows you to get information about your LD2410 Sensor.
#Bluetooth sensor is only useful of you have a B or C model
#text_sensor:
# - platform: ld2410
# version:
# name: ${friendly_name} LD2140 Firmware Version
#mac_address:
#name: ${friendly_name} LD2140 BT MAC Address
#############################################
# Binary Sensors
# https://esphome.io/components/binary_sensor/index.html
#############################################
binary_sensor:
# - platform: ld2410
# has_target:
# name: ${friendly_name} Presence
# has_moving_target:
# name: ${friendly_name} Moving Target
# has_still_target:
# name: ${friendly_name} Still Target
# out_pin_presence_status:
# name: ${friendly_name} LD2140 Out Pin Presence Status
#Standard PIR Sensor
- platform: gpio
pin:
number: GPIO13
mode:
input: True
pullup: True
inverted: True
filters:
- delayed_on: 200ms
name: ${friendly_name} PIR Sensor
device_class: motion
#RF Input from Vibration Sensor (Green Bin)
- platform: gpio
pin:
number: GPIO04
mode:
input: true
pullup: true
inverted: True
filters:
- delayed_on: 20ms
name: ${friendly_name} Green Bin motion
device_class: vibration
#RF Input from Vibration Sensor (Red Bin)
- platform: gpio
pin:
number: GPIO15
mode:
input: true
pullup: true
inverted: True
filters:
- delayed_on: 20ms
name: ${friendly_name} Red Bin motion
device_class: vibration