"""Smoke Sensor."""
|
|
import logging
|
|
|
|
import zigpy.profiles.zha
|
|
from zigpy.quirks import CustomCluster, CustomDevice
|
|
import zigpy.types as t
|
|
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time
|
|
from zigpy.zcl.clusters.security import IasZone
|
|
|
|
from zhaquirks import Bus
|
|
from zhaquirks.const import (
|
|
DEVICE_TYPE,
|
|
ENDPOINTS,
|
|
INPUT_CLUSTERS,
|
|
MODELS_INFO,
|
|
OUTPUT_CLUSTERS,
|
|
PROFILE_ID,
|
|
ZONE_STATUS,
|
|
ZONE_TYPE,
|
|
)
|
|
from zhaquirks.tuya import TuyaManufCluster, TuyaManufClusterAttributes
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
|
|
TUYA_SMOKE_DETECTED_ATTR = 0x0401 # [0]/[1] [Detected]/[Clear]!
|
|
|
|
|
|
class TuyaSmokeDetectorCluster(TuyaManufClusterAttributes):
|
|
"""Manufacturer Specific Cluster of the TS0601 smoke detector."""
|
|
|
|
attributes = {
|
|
TUYA_SMOKE_DETECTED_ATTR: ("smoke_detected", t.uint8_t, True),
|
|
}
|
|
|
|
def _update_attribute(self, attrid, value):
|
|
super()._update_attribute(attrid, value)
|
|
if attrid == TUYA_SMOKE_DETECTED_ATTR:
|
|
if value == 0:
|
|
self.endpoint.device.ias_bus.listener_event(
|
|
"update_zone_status", IasZone.ZoneStatus.Alarm_1
|
|
)
|
|
else:
|
|
self.endpoint.device.ias_bus.listener_event("update_zone_status", 0)
|
|
else:
|
|
_LOGGER.warning(
|
|
"[0x%04x:%s:0x%04x] unhandled attribute: 0x%04x",
|
|
self.endpoint.device.nwk,
|
|
self.endpoint.endpoint_id,
|
|
self.cluster_id,
|
|
attrid,
|
|
)
|
|
|
|
|
|
class TuyaIasZone(CustomCluster, IasZone):
|
|
"""IAS Zone."""
|
|
|
|
_CONSTANT_ATTRIBUTES = {ZONE_TYPE: IasZone.ZoneType.Fire_Sensor}
|
|
|
|
def __init__(self, *args, **kwargs):
|
|
"""Init."""
|
|
super().__init__(*args, **kwargs)
|
|
self.endpoint.device.ias_bus.add_listener(self)
|
|
|
|
def update_zone_status(self, value):
|
|
"""Update IAS status."""
|
|
super()._update_attribute(ZONE_STATUS, value)
|
|
|
|
|
|
class TuyaSmokeDetector0601(CustomDevice):
|
|
"""TS0601 Smoke detector quirk."""
|
|
|
|
def __init__(self, *args, **kwargs):
|
|
"""Init."""
|
|
self.ias_bus = Bus()
|
|
super().__init__(*args, **kwargs)
|
|
|
|
signature = {
|
|
MODELS_INFO: [
|
|
("_TZE200_aycxwiau", "TS0601"),
|
|
("_TZE200_ntcy3xu1", "TS0601"),
|
|
("_TZE200_vzekyi4c", "TS0601"),
|
|
("_TZE200_uebojraa", "TS0601"),
|
|
],
|
|
ENDPOINTS: {
|
|
1: {
|
|
PROFILE_ID: zigpy.profiles.zha.PROFILE_ID,
|
|
DEVICE_TYPE: zigpy.profiles.zha.DeviceType.SMART_PLUG,
|
|
INPUT_CLUSTERS: [
|
|
Basic.cluster_id,
|
|
Groups.cluster_id,
|
|
Scenes.cluster_id,
|
|
TuyaManufCluster.cluster_id,
|
|
],
|
|
OUTPUT_CLUSTERS: [
|
|
Time.cluster_id,
|
|
Ota.cluster_id,
|
|
],
|
|
},
|
|
},
|
|
}
|
|
|
|
replacement = {
|
|
ENDPOINTS: {
|
|
1: {
|
|
PROFILE_ID: zigpy.profiles.zha.PROFILE_ID,
|
|
DEVICE_TYPE: zigpy.profiles.zha.DeviceType.IAS_ZONE,
|
|
INPUT_CLUSTERS: [
|
|
Basic.cluster_id,
|
|
Groups.cluster_id,
|
|
Scenes.cluster_id,
|
|
TuyaIasZone,
|
|
TuyaSmokeDetectorCluster,
|
|
],
|
|
OUTPUT_CLUSTERS: [
|
|
Time.cluster_id,
|
|
Ota.cluster_id,
|
|
],
|
|
},
|
|
},
|
|
} |